The defibrillator is used to restore the heart rate. It is more common to use electrical defibrillation, which impinges on the heart with a certain amount of current, thereby terminating ventricular fibrillation.
AM-8000C
The defibrillator is used to restore the heart rate. It is more common to use electrical defibrillation, which impinges on the heart with a certain amount of current, thereby terminating ventricular fibrillation. Generally speaking, 85% -90% of patients with cardiac arrest in the early stage are ventricular fibrillation, and the most effective way to treat ventricular fibrillation is to perform defibrillation. For every 1 minute delay in defibrillation, the survival rate decreases by 7% -10%. The unexpected sudden death is also called sudden death. Such patients can actually survive if they are properly defibrillated. It should be noted that after defibrillation treatment, the patient’s heart rate, heart rhythm, breathing, blood pressure, complexion, limb condition, and embolism should be continuously observed, and records should be made at any time.
Standard configuration
1. Standard defibrillator+ECG
2. Standard defibrillator+ECG+NIBP+Spo2+pulse+temp
Feature
Screen 7 inches (16.5 cm) diagonal, non-fade.Type: color (TFT)
Display Resolution: 800 x 600 pixels.
Sweep Speed: 12.5mm/s, 25mm/s, 50mm/s
Defibrillator type: Manual, Synchronized, A synchronized,
Output waveform: Biphasic technology
Technical specifications
DEFIBRILLATOR.
(1) Defibrillator type Manual, Synchronized, Asynchronized,
(2) Energy accuracy: ∠+1%
(3) Energy selection: 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joules (nominal at a resistance of 50)
(4) Charging time Maximum: 10 seconds to 360 Joules
(5) Standard Adult/Pediatric Paddles Reusable external adult paddles (pediatric paddles integrated)
Power requirements.
(a) AC Power supply 100V~240V,50Hz/60 Hz
(b) Vehicle Voltage(Option) DC 12V
Internal Battery Backup
(1) Battery type Rechargeable lead-acid battery (12V 2.0Ah X2)
(2) Charging time Time-Minimum of 4 hours for full charging
(3) Battery charging During AC Power Supply operation of the device.
(4) Charging /Low Battery Indication Red LED
(5) Battery Capacity 100% of the battery will provide 120-min monitoring; and 35 discharges at 360 joules.
Display
– LCD Dimensions: 7-inch
– Type High resolution true-color graphic
– Resolution: 480X234
ECG
ECG lead: Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V1~V6
S-T segment analysis: -2.0~2.0mv
Arrhythmia analysis: yes
Protection: With stand 4000vAc/ 50Hz voltage in isolation and work against electrosurgical knife and defibrillation
Respiration
Measurement method: Thoracic impedance
NIBP
Working mode: Manual/Automatic/stat(5 minutes)
Method: Automatic oscillation
Cuff type: standard Adult; optional Pediatric/Neonatal
Temperature
Measurement range: 20~45℃
Resolution: 0.1℃
Pulse Oximetry(spO2)
Display: spo2 value, pulse histogram, waveform, Pulse
Range: 0~99%for adult, pediatric and neonatal patients
Probe: standard adult finger clip
Optional pediatric Y-type clip and neonatal wrap
Pulse range
Pulse range: 0-255bpm
Standard parameter & configuration
ECG/ RESP/SPO2/TEMP/PR/NIBP/DEFIBRILLATOR
Optional parameter
Recorder, Li-ion battery (11.1V 4Ah X2)
About us
Our Service:
1. Warranty period: main unit:2 years,accessories:6 months.
2. Technical support: installation,replancement of accessories,after sales service.
3. Return of goods: Yes,for any quality problem.
FAQ
OEM service: Yes,with clients’ informations on machines,manual,packages.
Payment: TT,LC at sight and Westernunion.
MOQ: 1 unit
Free sample: NO
Package and shipping
Delivery date: 3-7 working days after full payment.
Package: strong carton,plastic bag.wooden casing
Goods deliveried by UPS,DHL,by Air or by sea,
All follow customers’ idea.just choose economic ones